1
Нэлли
no recommendations
no complaints
Project title: Calculate the production of ethylene
Type of cooperation: One-time project
Section: Education and consulting
Prepayment: without prepayment
Payment methods: Bank transfer
Acceptance of requests: from 2025-07-07 until 2025-07-12
Type of cooperation: One-time project
Section: Education and consulting
Prepayment: without prepayment
Payment methods: Bank transfer
Acceptance of requests: from 2025-07-07 until 2025-07-12
Project description:
Offering additional earnings for a specialist in performing calculations in Aspen HYSYS. It is necessary to make calculations for the educational project of obtaining ethylene from pyrotase on the example of real production:
- preparation of material balance (each process and the general);
- drawing up a scheme of material flows;
- determination of parameters of the mode of operation of the rectification column (top temperature, bottom temperature, pressure in the column);
Calculation of the minimum and actual phlegm number;
26.
- compiling the thermal balance of the column and determining the steam flow rate in the boiler;
Determination of heat load on the condenser and flow rate
Refrigerant;
- calculation of the number of plates;
Determination of hydraulic resistance of plates;
calculation of the column for the action of wind and seismic forces
(At a height of more than 10 m);
- mechanical calculation;
- calculation of the boiler;
- Calculation of the distillate refrigerator.
- selection of standard equipment.
Offering additional earnings for a specialist in performing calculations in Aspen HYSYS. It is necessary to make calculations for the educational project of obtaining ethylene from pyrotase on the example of real production:
- preparation of material balance (each process and the general);
- drawing up a scheme of material flows;
- determination of parameters of the mode of operation of the rectification column (top temperature, bottom temperature, pressure in the column);
Calculation of the minimum and actual phlegm number;
26.
- compiling the thermal balance of the column and determining the steam flow rate in the boiler;
Determination of heat load on the condenser and flow rate
Refrigerant;
- calculation of the number of plates;
Determination of hydraulic resistance of plates;
calculation of the column for the action of wind and seismic forces
(At a height of more than 10 m);
- mechanical calculation;
- calculation of the boiler;
- Calculation of the distillate refrigerator.
- selection of standard equipment.